z
If not within the specification, replace the starter.
Starter no-load test voltage 11 V
Starter no-load test current 90 A or less
Fig. 3: Connecting Starter, Battery, And A Tester
Courtesy of MAZDA MOTORS CORP.
MAGNETIC SWITCH OPERATION INSPECTION
Pull-out test
1. Verify that the starter motor pinion is extended while battery positive voltage is connected to terminal S
and the starter body is grounded.
z
If the starter motor pinion is not extended, repair or replace the starter.
Fig. 4: Checking Battery Positive Voltage Terminal S And Starter Body
Courtesy of MAZDA MOTORS CORP.
NOTE:
z
Depending on the battery charge condition, the starter motor pinion may
rotate while in an extended state. This is due to current flowing to the
starter motor through the pull-in coil to turn the starter motor, and does
not indicate an abnormality.
2008 Mazda CX-9 Grand Touring
2008 ENGINE Starting System (MZI-3.7) - Mazda CX-9
Microsoft
Sunday, November 15, 2009 9:56:47 AM
Page 3
© 2005 Mitchell Repair Information Company, LLC.