DIAGNOSTIC PROCEDURE
DTC B241A - DIAGNOSTIC PROCEDURE
CONDITION
more.
POSSIBLE CAUSE
z
Short to GND in wiring harness between PLG control module terminal 3A and
PLG touch sensor (RH) terminal B
z
Short to GND in wiring harness between PLG control module terminal 3B and
PLG touch sensor (LH) terminal B
z
PLG touch sensor malfunction
z
PLG control module malfunction
STEP
INSPECTION
ACTION
1
INSPECT PLG TOUCH SENSOR
z
Inspect the PLG touch sensor.
(See
POWER LIFTGATE (PLG)
TOUCH SENSOR
INSPECTION
.)
z
Is the touch sensor normal?
Yes Go to the next step.
No
Replace the PLG touch sensor.
(See
POWER LIFTGATE (PLG) TOUCH
SENSOR REMOVAL/INSTALLATION
.)
Go to Step 3.
2008 Mazda CX-9 Grand Touring
2008 BODY & ACCESSORIES On-Board Diagnostic (Power Liftgate (PLG) System) - Mazda CX-9
Microsoft
Sunday, November 15, 2009 10:46:08 AM
Page 12
© 2005 Mitchell Repair Information Company, LLC.