DIAGNOSTIC PROCEDURE
DTC B267A - DIAGNOSTIC PROCEDURE
STEP
INSPECTION
ACTION
1
INSPECT WIRING HARNESS BETWEEN
PLG CONTROL UNIT AND LIFTGATE
LATCH AND LOCK ACTUATOR
z
Disconnect the PLG control module
connector.
z
Disconnect the liftgate latch and lock
actuator connector.
z
Inspect the wiring harness between PLG
control module terminal 3H and liftgate
latch and lock actuator terminal B for an
open circuit/short circuit to ground
system.
Yes Go to the next step.
No
Repair or replace the wiring harness.
Go to Step 3.
2008 Mazda CX-9 Grand Touring
2008 BODY & ACCESSORIES On-Board Diagnostic (Power Liftgate (PLG) System) - Mazda CX-9
Microsoft
Sunday, November 15, 2009 10:46:08 AM
Page 23
© 2005 Mitchell Repair Information Company, LLC.