Battery slow charge current
80D26L (55): 5.5-6.5 A
Battery quick charge current [30 min]
80D26L (55): 35 A
Generator standard voltage [IG-ON]
Terminal B: B+
Terminal A: B+
Terminal RC: Approx. 1 V or less
Terminal LI: Approx. 1 V
Generator standard voltage [Idle, 20°C
{68°F}]
Terminal B: 12-16 V
Terminal A: 12-16 V
Terminal RC: 0-16 V
Terminal LI: 1-16 V
Generator generated current minimum
value
70 % of the nominal output current (nominal output current: 110
A)
[Ambient temp. 20°C {68°F}, voltage 13.0-15.0 V, both engine
and generator are hot]
Generator rotor resistance (between slip
rings) [20°C {68°F}]
1.8-2.2 ohm
Generator brush length
Standard: 22.5 mm {0.89 in}
Minimum: 5.0 mm {0.20 in}
Generator brush spring force
Standard: 4.1-5.3 N {0.42-0.54 kgf, 0.92-1.19 lbf}
Minimum: 1.7 N {0.17 kgf, 0.38 lbf}
Ignition coil secondary coil resistance
5-6 kilohms
Firing order
1-4-2-5-3-6
Spark plug type
CY01 18 110
Spark plug gap
1.29-1.45 mm {0.051-0.057 in}
Spark plug resistance
2-20 kilohms
2008 Mazda CX-9 Grand Touring
2008 ENGINE Technical Data (MZI-3.7) - Mazda CX-9
Microsoft
Sunday, November 15, 2009 10:03:12 AM
Page 2
© 2005 Mitchell Repair Information Company, LLC.