1. Follow "BEFORE SERVICE PRECAUTION" before performing any work operations to prevent fuel
from spilling from the fuel system. (See
BEFORE SERVICE PRECAUTION [MZI-3.7]
.)
2. Disconnect the negative battery cable.
3. Remove the fuel pump unit. (See
FUEL PUMP UNIT REMOVAL/INSTALLATION [MZI-3.7]
.)
4. Siphon the fuel from the fuel tank.
5. Verify that the nonreturn valve is closed.
z
If malfunction, replace the fuel tank. (See
FUEL TANK REMOVAL/INSTALLATION [MZI-
3.7]
.)
6. Verify that the nonreturn valve is not stuck open and does not open even when pulled up by a finger.
z
If malfunction, replace the fuel tank. (See
FUEL TANK REMOVAL/INSTALLATION [MZI-
3.7]
.)
Fig. 25: Identifying Nonreturn Valve
Courtesy of MAZDA MOTORS CORP.
FUEL PUMP UNIT REMOVAL/INSTALLATION [MZI-3.7]
facility breakage. Fuel can also irritate skin and eyes. To prevent
this, always complete the "Fuel Line Safety Procedure", while
referring to the "BEFORE SERVICE PRECAUTION".
NOTE:
z
Nonreturn valve is integrated in the fuel tank.
z
The nonreturn valve is normally closed by the spring force.
z
Verify the nonreturn valve operation using a mirror.
WARNING:
z
Fuel line spills and leakage are dangerous. Fuel can ignite and cause
serious injuries or death and damage. Fuel can also irritate skin and
eyes. To prevent this, always complete the "Fuel Line Safety
Procedure".
z
Fuel line spills and leakage are dangerous. Fuel can ignite and cause
serious injuries or death and damage. Fuel can also irritate skin and
eyes. To prevent this, before performing the fuel pump unit
2008 Mazda CX-9 Grand Touring
2008 ENGINE Fuel System (MZI-3.7) - Mazda CX-9
Microsoft
Sunday, November 15, 2009 10:04:45 AM
Page 21
© 2005 Mitchell Repair Information Company, LLC.