Are all items normal?
10
Connect the M-MDS to the DLC-2.
Turn ignition switch to the ON position.
(Engine off)
Access TR PID.
Is TR PID indicated P/N when selecting P
or N position
Yes
Go to the next step.
No
Inspect TR switch is adjusted properly,
inspect for open or short circuit between TR
switch and TCM.
Repair or replace components as required.
Then go to the next step.
11
Is clicking sound heard from starter relay
when the ignition switch is turned to
START?
Yes
Go to step 14.
No
Go to the next step.
12
Inspect the starter relay and following
harnesses.
Between starter relay and PCM
Between starter relay and ignition switch
(See: 09-21-6 RELAY INSPECTION)
Are they normal?
Yes
Go to the next step.
No
Repair or replace components as required.
Then go to step 11.
13
Inspect IGNITION switch and related
harnesses.
(See: 09-21-2 IGNITION SWITCH
INSPECTION)
Are they normal?
Yes
Go to the next step.
No
Repair or replace components as required.
Then go to step 11.
14
Inspect the following harnesses.
Between starter relay and Battery
Between starter relay and Starter
Are they normal?
Yes
Go to the next step.
No
Repair or replace as required.
Then go to next step.
15
Inspect the starting system.
(See: 01-19-2 STARTER INSPECTION
[MZI-3.7])
Is starting system normal?
Yes
Go to the next step.
No
Repair or replace components as required.
16
Inspect for seized/hydro locked engine or
flywheel.
Is ENGINE seized or hydro locked?
Yes
Repair or replace components as required.
No
Go to the next step.
17
Connect the M-MDS to the DLC-2.
Retrieve any continuous memory DTCs.
Are there any continuous memory DTCs
Yes
DTC is displayed:
Go to appropriate DTC inspection.
(See
DTC TABLE [MZI-3.7]
.)
Communication error message is
displayed:
Inspect for the following:
z
Open circuit in wiring harness
between main relay and PCM
terminal 1BO or 1BJ
z
Open circuit in wiring harness
between main relay terminal E and
PCM terminal 1BM
2008 Mazda CX-9 Grand Touring
2008 ENGINE Symptom Troubleshooting (MZI-3.7) - Mazda CX-9
Microsoft
Sunday, November 15, 2009 10:10:04 AM
Page 20
© 2005 Mitchell Repair Information Company, LLC.