CONTINUITY INSPECTION OF SHORT WIRING HARNESS CONNECTOR
1. Verify that the continuity between the short wiring harness connector terminals is as indicated in the
table.
z
If the continuity is not as indicated in the table, replace the short wiring harness connector.
(2)
BSM control module (LH) only
NOTE:
z
Terminal voltage of both the left and right BSM control modules is
equivalent