STEP
INSPECTION
ACTION
1
VERIFY FREEZE FRAME DATA HAS
BEEN RECORDED
z
Has FREEZE FRAME DATA been
recorded?
Yes Go to the next step.
No
Record FREEZE FRAME DATA on the
repair order, then go to the next step.
2
VERIFY RELATED REPAIR
INFORMATION AVAILABILITY
z
Verify related Service Bulletins and/or
on-line repair information availability.
z
Is any related Service Bulletins
available?
Yes
Perform repair or diagnosis according to the
available Service Bulletins.
z
If the vehicle is not repaired, go to the
next step.
No
Go to the next step.
3
INSPECT GENERATOR TERMINAL
FOR POOR INSTALLATION
z
Turn the engine switch off.
z
Inspect generator terminal B for
looseness.
z
Are there any malfunction?
Yes Connect generator terminal B correctly, then
go to Step 9.
No
Go to the next step.
4
INSPECT GENERATOR CIRCUIT FOR
SHORT TO POWER SUPPLY
z
Turn the ignition switch to the ON
position (Engine off).
z
Measure the voltage between the
following terminals:
{
Generator terminal RC (wiring
harness-side) and body ground.
{
Generator terminal LI (wiring
harness-side) and body ground.
z
Is the voltage B+?
Yes Repair or replace suspected part, then go to
Step 9.
No
Go to the next step.
5
INSPECT PCM CONNECTOR FOR
POOR CONNECTION
z
Turn the engine switch off.
z
Inspect for poor connection (such as
damaged/pulled-out terminals,
corrosion).
z
Are there any malfunction?
Yes
Repair or replace suspected part, then go to
Step 9.
No
Go to the next step.
INSPECT GENERATOR CIRCUIT FOR
OPEN CIRCUIT
z
Inspect for continuity between generator
Yes Go to the next step.
2008 Mazda CX-9 Grand Touring
2008 ENGINE PERFORMANCE On-Board Diagnostic (MZI-3.7) - Mazda CX-9
Microsoft
Sunday, November 15, 2009 10:08:40 AM
Page 289
© 2005 Mitchell Repair Information Company, LLC.