ATM-BCH (ATM B-Channel Trunk)
Issue 4 May 2002
10-203
555-233-123
ISDN Test Call Test (#258)
This non-destructive test performs a far-end looparound test over an ATM-BCH
trunk if
■
the trunk is IN-SERVICE, MAINTENANCE/NEAR-END, or
OUT-OF-SERVICE/NEAR-END
■
no calls are active on the trunk
■
the system uses country protocol 1 (including US) or the far-end has
looparound capability
The test sets up a call to a far-end switch over the ATM-BCH trunk. Then the
digital port on a TN711D Maintenance/Test circuit pack sends a bit pattern to the
far-end and back. If the received pattern matches that sent, the test passes. If
there are differences, it fails.
Table 10-71. TEST #257 Call State Audit Test
Error
Code
Test
Result
Description/Recommendation
1018
ABORT
Maintenance disabled
1. Enable maintenance by entering y in the
Maintenance
Tests?
field on page 2 of the change trunk-group form.
1019
ABORT
Audit already in progress
1. Wait 2 minutes, and try again.
1113
ABORT
Signaling link failed
1. Check the results of Test #255 (Signaling Link State Check).
1114
ABORT
Signaling link in transitional state
1. Retry the command up to 5 times at 1-minute intervals.
1116
ABORT
Trunk out-of-service
1. Check the trunk service state (status trunk grp#/mbr#).
2100
ABORT
Could not allocate needed resources
1. Retry the command up to 5 times at 1-minute intervals.
FAIL
Internal system error
1. Retry the command up to 5 times at 1-minute intervals.
PASS
1. Wait 4 minutes, then check the Error Log for call-state
mismatches. If a call state mismatch is found, the call is torn
down.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...