TIE-TRK (Tie Trunk)
Issue 4 May 2002
10-1773
555-233-123
Tie Trunk EPF Test (#74)
This test consists of an E lead and M lead test. The E lead test checks for the
proper activation and deactivation of the port’s E lead. The M lead test checks the
M lead EPF current flow. The processor sends an M lead test request to the circuit
pack and receives the results. The returned results are measured to see if a port
or external tie trunk line fails.
3
FAIL
(TN439 circuit packs only.) No dial tone detected from the
other end.
1. Retry the command at one minute intervals a maximum
of 5 times.
2. If the test continues to fail, check the far-end PBX to
ensure a translation match at both ends.
3. Check the facility.
PASS
The relevant seizure test passes. This port is functioning
properly.
1. If users are reporting troubles, examine loop
connections to the port, wiring, and stations.
0
NO
BOARD
The test could not relate the internal ID to the port (no
board).
1. Check to ensure that the board translations are correct.
Translate the board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish
the linkage between the internal ID and the port.
Table 10-650.
Seizure Tests (#73, #747, #73) — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...