Maintenance Object Repair Procedures
555-233-123
10-1106
Issue 4 May 2002
1003
ABORT
The system could not allocate a tone receiver for the test.
The system may be oversized for the number of Tone
Detectors present or some Tone Detectors may be
out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present,
refer to TTR-LEV (TTR level) Maintenance
documentation.
2. Look for TONE-PT errors in the Error Log. If present,
refer to TONE-PT (Tone generator) Maintenance
documentation.
3. If neither condition exists, retry the test at one-minute
intervals a maximum of 5 times.
1004
ABORT
The port has been seized by a user for a valid call.
Determine whether the port is available for testing.
1. Retry the command at one-minute intervals a
maximum of 5 times.
1020
ABORT
The test did not run due to a previously existing error on the
specific port or because of a more general circuit pack
error.
1. Examine the Hardware Error Log for existing errors
against this port or the circuit pack, and attempt to
diagnose the previously existing errors.
2000
ABORT
The response to the test request was not received within
the allowable time period.
2012
ABORT
Internal System Error.
2100
ABORT
System resources required for this test are not available.
2103
ABORT
The system could not make the conference connection for
the test.
1. Retry the command at one-minute intervals a
maximum of 5 times.
Table 10-416.
TEST #97 Modem Pool Conference Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...