Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-100
Issue 4 May 2002
Field descriptions
Cause
Reason for the restart:
■
Active Down: (High or Critical Reliability system only) The Active
SPE went into SPE Down mode. The Duplication Interface
initiated an SPE-interchange to the Standby SPE. If this initcause
triggers an SPE interchange when the Standby is NOT in
Maintenance mode, the previous entry in the log may actually
represent a restart that occurred on the Standby SPE. See the
preceding description of display initcauses for a complete
explanation. If a High or Critical Reliability system does a PEI with
a warm start, the system software often requests a Cold 2 restart
to recover properly only minutes after the warm start has
occurred.
■
Bad Handshake: (High or Critical Reliability system only) The
Duplication Interface received inconsistent handshakes from the
Active SPE. Thus, the Duplication Interface initiated an
SPE-interchange to the Standby SPE. If this initcause triggers an
SPE interchange when the Standby is NOT in Maintenance
mode, the previous entry in the log may actually represent a
restart that occurred on the Standby SPE. See the preceding
description of display initcauses for a complete explanation. If a
High or Critical Reliability System does a PEI with a warm start,
the system software often requests a COLD 2 restart to recover
properly only minutes after the warm start has occurred.
■
Bad Memory: A defective memory circuit pack generating too
many errors caused a restart.
■
System Technician Request: The restart was performed
because of system technician demand. A system
technician-requested reset system 4 command entry should
always precede an upgrade software command entry.
■
Failed Interchange: A “hot-start” interchange (system
technician-demanded, scheduled, or software-requested) failed
because shadowing was disabled.
■
Initialized: This is always the first entry in the history and is
present until more than 15 restarts have been performed. It
indicates power-up and also occurs if the Maintenance/Tape
Processor is reset during initialization.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...