Maintenance Object Repair Procedures
555-233-123
10-1446
Issue 4 May 2002
Automatic Download Actions
1. System Reboot/Restart
A global download action is initiated when periodic maintenance tests
begin after a system reboot/restart, regardless of whether the parameters
have been downloaded previously.
2. Periodic Tests
If the download flag is still set when periodic tests are run on a terminal, a
download action will occur. This action is required in case a terminal could
not be downloaded previously, because:
■
It was off-hook at the time the system first booted, or
■
The terminal was off-hook at the time the translation associated with
downloadable parameters was changed.
NOTE:
It may take more than an hour for periodic tests to reach the terminal
that needs to be downloaded.
3. Terminal Administration
A downloadable terminal is automatically downloaded when translation
changes associated with downloadable parameters are made as part of
system administration. As shown in the previous table, these changes can
be for a specified terminal or may be system-wide. If the change is for a
system-level parameter, a background global update request must be
submitted to download all programmable terminals.
NOTE:
This global update may take more than an hour for a system with
several thousand programmable terminals.
4. Port Insertion
Whenever maintenance software initiates a request to place a port into
service, a terminal download action is begun on that terminal, if that
terminal is programmable. This port insertion action occurs under the
following circumstances:
■
A digital line circuit pack that is physically inserted into the system
and has ports currently administered for programmable terminals.
■
A station port is added to the system by an add station or change
station command.
■
A TTI port is activated.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...