Maintenance Object Repair Procedures
555-233-123
10-1774
Issue 4 May 2002
Table 10-651.
TEST #74 Tie Trunk EPF Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run the
test. This could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1
ABORT
Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1000
ABORT
System resources required to run this test are not available.
The trunk may be busy with a valid call. Use display trunk xx
to determine trunk group/member number of the port. Use
status trunk to determine the service state of the port. If the
service state indicates that the port is in use, then the port is
unavailable for certain tests. You must wait until the port is
idle before retesting.
1. If the port status is active, but the port is not in use (no
calls), then check the Error Log for Error Type 1025 (see
Error Log table for description of this error and required
actions). The port may be locked up. The far-end PBX
may not be releasing.
2. If the port status is idle, then retry the command at
1-minute intervals a maximum of 5 times.
1004
ABORT
The port was seized by a valid call during the test. The test
has been aborted. Use display trunk xx to determine the
trunk group/member number of the port. Use status trunk to
determine the service state of the port. If the service state
indicates that the port is in use, the port is unavailable for
certain tests. (Refer to the “Status Commands” section in
Chapter 8, ‘‘Maintenance Commands and Trouble-Clearing
Aids’’
for a full description of all possible states.) You must
wait until the port is idle before retesting.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, and the port is not in use,
escalate the problem.
1005
ABORT
This test is not valid for this trunk translation. Must be a
Type-1 standard trunk for this test to run.
1. Check trunk configuration. If it is not a Type-1 standard
trunk, this abort message should be ignored.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...