Maintenance Object Repair Procedures
555-233-123
10-834
Issue 4 May 2002
37
FAIL
The update files, load vintages, and translations are
different in both SPEs. The Active SPE has the most
current update file and translations.
38
FAIL
The update files, load vintages, and translations are
different in both SPEs. The Active SPE has the most
current update file, and the Standby SPE has the most
current translations.
1. Follow the procedures for Error Code 4 to get the
correct load vintage. After running test card-mem
long, check for Error Codes 32 or 64. Follow the
recovery procedure under the applicable error code.
40
FAIL
The update files and announcements are different in both
SPEs. The Active SPE has the most current update file and
announcements.
1. Issue save announcements to save announcements
on both SPEs.
2. Have INADS issue copy update-file to copy the
update file from the Active to the Standby SPE.
3. Run test card-mem long to resolve the alarms.
41
FAIL
The update files, translations, and announcements are
different in both SPEs. The Active SPE has the most
current update file, translations, and announcements.
42
FAIL
The update files, translations, and announcements are
different in both SPEs. The Active SPE has the most
current update file and announcements, and the Standby
SPE has the most current translations.
1. Issue the save translations command.
2. Issue the save announcements command.
3. Have INADS issue the copy update-file command to
copy the update file from the Active to the Standby
SPE.
4. Reissue test card-mem long to resolve the alarms.
Table 10-303.
TEST #421 Flash Data Consistency Check Test — Continued
Error Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...