ETR-PT (Enhanced Tone Receiver Port)
Issue 4 May 2002
10-757
555-233-123
1-122
FAIL
DTMF digits were not detected correctly.
1. Run the short test sequence via the test port PCSSpp sh
r 1 command.
2. If the problem persists, the system is still operating
properly but capacity will be reduced. To restore
performance to normal, replace the circuit pack containing
the defective ETR-PT (Enhanced Tone Receiver Port).
Follow the procedures described in the TONE-BD section
for replacing a tone/clock circuit pack.
102
FAIL
2225 Hz Modem Answer Tone was not detected correctly. This
will impact call-classification operation.
1. Run the short test sequence via the test port PCSSpp sh r
1 command.
2. If the problem persists, the system can still operate
properly but capacity will be reduced. In order to restore
performance to normal, replace the circuit pack containing
the defective port. Follow the procedures described in the
TONE-BD section for replacing a tone/clock circuit pack.
130
FAIL
Forward or Backward MFC signals were not correctly
generated or detected. This will impact MFC calls.
1. Run the short test sequence via the test port PCSSpp sh r
1 command.
2. If the problem persists, the system can still operate
properly but capacity will be reduced. In order to restore
performance to normal, replace the TN2182 circuit pack
containing the defective ETR-PT. Follow the procedures
described in the TONE-BD section for replacing a
tone/clock circuit pack.
PASS
Tone Detection Verification is successful. The ETR Port is able
to detect/generate all necessary tones.
Table 10-285.
TEST #42 Tone Detection Verification Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...