Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-54
Issue 4 May 2002
System resets, that are less severe than a reboot, rarely affect the error and alarm
logs.
NOTE:
If the error and alarm logs contain SYSTEM errors, then use display
initcauses to search for information that the system could not log during
reset operation.
Feature Interactions
■
If the user disables the alarm origination with the change system
parameters-maintenance command, then the
Ack?
(Acknowledged) field
on the Alarm Report is blank regardless of the true acknowledged state of
the alarm.
Options screen
Use display alarms to show the options screen, and select the options you want
to view on the report. The figure below is an example of the options screen for
Alarm Reports.
Action/
Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
display
alarms
schedule
Report sent to printer
Command is validated and
then a scheduling form
displays to schedule
execution of the command.
The command is then placed
in the command queue and is
executed at the specified
time. The information
displayed by the command is
sent to the system printer
instead of the screen.
1
Examples:
display alarms
display alarms print
display alarms schedule
1
Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
cust
rcust
bcms
browse
all alarms
displayed
see below
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...