Maintenance Object Repair Procedures
555-233-123
10-914
Issue 4 May 2002
Table 10-332.
INADS Link Error Log Entries Test
Error
Code
Test
Result
Description/Recommendation
1
0
The call was successfully placed to INADS. No trouble found.
2
0
Informative error indicating that alarm origination was disabled
at the time of the test. The test runs even if alarm origination is
disabled.
1. If Alarm Origination is desired, then enable this feature via
the Maintenance-Related System Parameters Form.
2. Repeat the test.
3
0
The INADS connection is currently in use.
1. Wait 10 minutes and retry this command.
4
0
INADS did not answer the alarm origination call.
1. Verify INADS is up and running.
2. Verify the INADS phone number and switch product id are
correct via the Maintenance-Related System Parameters
Form.
3. Enable alarm origination via the Maintenance-Related
System Parameters Form and test the PR-MAINT
(Maintenance/Tape Processor) by issuing the test
processor a|b command. If PR-MAINT Tests #102 and
#103 do not pass, then refer to PR-MAINT
(Maintenance/Tape Processor) Maintenance
documentation.
4. Retry the command.
5
0
No INADS phone number administered.
1. Administer the INADS phone number via the
Maintenance-Related System Parameters Form.
2. Retry the command.
6
0
INADS did not send the acknowledgment message to the “test
inads alarm” message.
1. Verify the INADS phone number and switch product id are
correct via the Maintenance-Related System Parameters
Form.
2. Verify INADS is up and running.
3. Retry the command.
7
0
INADS sent a negative acknowledgment to the “test inads
alarm” message.
8
0
Internal system error; system received an invalid return code.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...