Maintenance Object Repair Procedures
555-233-123
10-1428
Issue 4 May 2002
Processor Bus Time-out Exception Test (#82)
This test is a nondestructive test. The test is used to verify that the RISC
Processor can intentionally cause a BUS TIMEOUT EXCEPTION (BTE) and then
verifies if it vectors to the correct interrupt routine. This is basically a test of the
internal operation of the RISC Processor chip and the bus time-out circuitry.
Table 10-539.
Test #82 Processor Bus Time-out Exception Test
Error
Code
Test
Result
Description/Recommendation
100
ABORT
The test did not complete within the allowable time period.
1. Retry the command.
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT
Refer to STBY-SPE for a description of these error codes.
2500
ABORT
Internal system error
1. Retry the command.
FAIL
The interrupt was not detected or acted upon.
1. Repeat the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to fail, the Processor circuit pack should
be replaced. The replacement must have enough memory
for this system.
NOTE:
If you replace the Processor circuit pack, you need
to obtain a new license file.
3. If replacement of the Processor circuit pack still results in
test failure, the following circuit packs should be replaced,
one at a time in the order provided: TN765 Processor
Interface, TN777B Network Control, TN778 Packet Control,
and TN772 Duplication Interface circuit packs. The test
should then be repeated.
PASS
The interrupt was correctly detected. The RISC Processor is
functioning correctly.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...