H323-STN (H.323 IP Station)
Issue 4 May 2002
10-883
555-233-123
Table 10-320.
TEST #1373 Signaling Path PING Test
Error
Code
Test
Result
Description/Recommendation
2100
ABORT
Could not locate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
1003
FAIL
Ping to the destination failed.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Investigate any C-LAN ethernet port errors.
1007
FAIL
The system could not PING the registered endpoint via the
C-LAN.
1. Verify that at least one destination reachable through this
port. PING this destination (ping ip-address
xxx.xxx.xxx.xxx).
2. If the PING to any destination is successful through this
port, the link is up.
3. If PING to all destinations fail, test the C-LAN port (test port
UUCSSpp short) and follow repair procedures for Session
Status Test (#1286) failures.
4. If only this station cannot be pinged:
■
Make sure the PC is up
■
Make sure the PC has a network connection (ethernet or
dialup)
■
Check the ethernet cabling
PASS
The system can successfully send IP packets to the registered
endpoint from the C-LAN.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...