Maintenance Object Repair Procedures
555-233-123
10-1392
Issue 4 May 2002
MTP Analog Loop Around Test (#103)
This test is a nondestructive test. The test does an on-board loop around by using
the MTPINADS channel. Test data is sent through the on-board modem out
toward the INADS trunk. The data is looped around before the actual trunk, and it
comes back into the on-board modem. The data is then verified for integrity.
NOTE:
The test does not send any data onto the INADS trunk. However, in order to
pass, the test does require the trunk to be present.
Table 10-517.
TEST #103 MTP Analog Loop Around Test
Error
Code
Test
Result
Description/Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT
(Refer to STBY-SPE Maintenance documentation for a
description of these error codes.)
1018
ABORT
The test has been disabled via administration.
1. To enable the test, issue the change system-parameters
maintenance command, and set the Test Remote Access
Port field to “y”. If you are testing the Standby PR-MAINT,
a refresh spe-standby command must be successfully
executed before you can proceed to Step 2.
2. Rerun the test.
1131
ABORT
The INADS port is busy because the system is reporting
alarms to INADS, or because INADS is dialed into the system.
1. Wait about 10 minutes and then re-enter the command.
10301
ABORT
System software resources required for this test are not
available.
10302
10309
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...