Maintenance Object Repair Procedures
555-233-123
10-836
Issue 4 May 2002
52
FAIL
The update files, load vintages, and announcements are
different in both SPEs. The Active SPE has the most
current update file, and the Standby SPE has the most
current announcements.
53
FAIL
The update files, load vintages, translations, and
announcements are different in both SPEs. The Active
SPE has the most current update file, and translations, and
the Standby SPE has the most current announcements.
54
FAIL
The update files, load vintages, translations, and
announcements are different in both SPEs. The Active
SPE has the most current update file and the Standby SPE
has the most current translations and announcements.
1. Follow the procedures for 4 to get the correct load
vintage. After running the test card-mem long, check
for Error Codes 32 or 64. Follow the recovery
procedure under the applicable error code.
64
FAIL
The update files are different in both SPEs. The update file
on the Standby SPE is the most current.
1. If you are on site with the switch, replace the Active
SPE memory card with the Standby SPE memory
card. If you are not on site with the switch, issue the
reset system interchange command. This action
causes the Standby SPE to become the Active SPE.
Refer to the “Reset Commands” section in Chapter 8,
“Maintenance Commands and Trouble-Clearing Aids”
for information on the side effects of a processor
interchange.
2. Have INADS issue copy update-file. If the update file
copy passes, go to Step 3.
3. Reissue test card-mem long to resolve the alarms.
65
FAIL
The update files and translations are different in both
SPEs. The Standby SPE has the most current update file,
and the Active SPE has the most current translations.
66
FAIL
The update files and translations are different in both
SPEs. The Standby SPE has the most current update file
and translations.
1. Issue save translations to save translations on both
SPEs.
2. Follow the procedures for Error Code 64.
Table 10-303.
TEST #421 Flash Data Consistency Check Test — Continued
Error Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...