Maintenance Object Repair Procedures
555-233-123
10-1354
Issue 4 May 2002
c. Error Type 513: PPP link lost end-to-end connectivity.
1. Test for hardware problem (test port UUCSSpp long).
2. Run TDM Looparound Test (#1285) and refer to repair procedures if
there is a hardware problem.
If there is no hardware problem, the switch tries to re-establish PPP
link.
d. Error Type 769: Port received an invalid frame, which
■
is greater than the maximum length
■
contains CRC errors
■
violates the link level protocol.
1. Test the port (test port UUCSSpp long).
2. Refer to TDM Port Looparound Test (#1285) to verify repair.
3. Clear the alarm (test port UUCSSpp long clear).
e. Error Type 1281: System software received an indication that the far-end
has requested a disconnect of a session on this link. This is a log-only
error.
f. Error Type 1537, 1538: Some or all port sessions (sockets) are down.
1. Test the port (test port UUCSSpp short).
2. Refer to Session Status Test (#1286) repair procedure to verify
repair.
g. Error Type 1793-1920: system software received an indication that a
socket was closed due to an error. Error Type indicates the application
associated with this socket.
Aux Data indicates the internal application number.
If the switch indicates that:
Then it:
Some of the sessions are down
Raises off-board WARNING
All of the sessions are down
Raises off-board MINOR alarm
Error Type
Application
1793
Unused
1794
DCS
1795
AUDIX
1796
CMS
1797
ISDN Gateway
1798-1920
Reserved for future
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...