Maintenance Object Repair Procedures
555-233-123
10-24
Issue 4 May 2002
ADX16D-B (16 Port AUDIX Circuit
Pack)
The ADX16D-BD maintenance object represents a TN566/TN2169 EMBEDDED
AUDIX circuit pack combination operating in 16 port mode digital (DP). For
circuit-pack-level problems, see “XXX-BD (Common Port Circuit Pack)”. Port-level
maintenance is covered by ADX16D-PT.
EMBEDDED AUDIX consists of 2 circuit packs that occupy 5 slots on a port
carrier. The tests described in this manual apply only to switch-side maintenance
which tests circuit pack components related to the TDM bus interface. The AUDIX
system has an extensive maintenance strategy of its own that is described in
EMBEDDED AUDIX System Maintenance, 585-300-110.
ADX16A-BD (AUDIX Circuit Pack)
The ADX16A-BD maintenance object represents a TN566/TN2169 EMBEDDED
AUDIX circuit pack combination operating in control-link (CL) mode. For
circuit-pack-level problems, see “XXX-BD (Common Port Circuit Pack)”. Port-level
maintenance is covered by ADX16A-PT.
EMBEDDED AUDIX consists of 2 circuit packs that occupy 5 slots on a port
carrier. The tests described in this manual apply only to switch-side maintenance
which tests circuit pack components related to the TDM bus interface. The AUDIX
system has an extensive maintenance strategy that is described in EMBEDDED
AUDIX System Maintenance, 585-300-110.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command To Run
1
1
UU is the universal cabinet number (1 for PPN, 2 - 3 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21).
Full Name of MO
ADX16D-B
MINOR
test board PCSS sh
AUDIX Circuit Pack
ADX16D-B
WARNING
test board PCSS sh
AUDIX Circuit Pack
MO Name (in
Alarm Log)
Alarm Level
Initial Command To
Run
1
1
UU is the universal cabinet number (1 for PPN, 2 - 3 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21).
Full Name of MO
ADXCL-BD or
\ADX16A-BD
MINOR, or
WARNINGS
test board PCSS sh
AUDIX Circuit Pack
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...