Maintenance Object Repair Procedures
555-233-123
10-1286
Issue 4 May 2002
Packet Control Reset Test (#586)
This test resets the Packet Control circuit pack, downloads Packet Control circuit
pack firmware form tape, and then causes the Packet Control circuit pack to begin
operation.
!
WARNING:
This test is destructive and disrupts service when run on the Packet Control
circuit pack in the Active SPE. This test is not destructive when run on the
Packet Control circuit pack in the Standby SPE of a High or Critical
Reliability system. When this test is run on the Packet Control circuit pack on
the Active SPE, the “busyout packet-control C” command must be executed
first. Once testing has been completed, a busied-out Packet Control should
be released via the release packet-control C command.
Table 10-482.
TEST #586 Packet Control Reset Test
Error
Code
Test
Result
Description/Recommendation
1029
2011
2012
2013
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT
Refer to STBY-SPE Maintenance documentation for a
description of these error codes.
1015
ABORT
The Packet Control circuit pack is not busied out.
1. Retry the command after running the busyout
packet-control C command.
1152
ABORT
The Packet Control circuit pack hardware was successfully
reset and the circuit pack was successfully put back into
service. However, a new image of Packet Control circuit pack
firmware was not able to be downloaded from the tape,
because the tape was unavailable. Nonetheless, the existing
firmware on the circuit pack is valid, and there is no need to
repeat this test.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...