Maintenance Object Repair Procedures
555-233-123
10-892
Issue 4 May 2002
1004
ABORT
The port was seized by a valid call during the test. The test has
been aborted. Use display port PCSSpp to determine the
station extension number of the port. Use status station to
determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for
certain tests. (Refer to the “Status Commands” section in
Chapter 10, “Maintenance Commands and Trouble-Clearing
Aids” for a full description of all possible states.) You must wait
until the port is idle before retesting. Attendants are always in
use (off-hook) if the handset is plugged in and the port is not
busied out.
1. Retry the command at one-minute intervals a maximum of
5 times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
1018
ABORT
Test disabled via administration. This only applies to analog
stations.
The default for this field is ‘y,’ so you may want to determine
why it has been turned off for this station.
1. To enable test, set the Test field on the station
administration screen for the particular analog station
being tested to ‘y.’ Use change station <extension>.
2000
ABORT
Response to the test request was not received within the
allowable time period.
1. Retry the command at one-minute intervals a maximum of
5 times.
2020
ABORT
The test did not run due to an already existing error on the
specific port or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or
the circuit pack and attempt to diagnose the already
existing error.
2100
ABORT
Could not allocate the necessary system resources to run this
test. This could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Table 10-324.
TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...