HYB-LINE (Hybrid Line)
Issue 4 May 2002
10-897
555-233-123
1001
ABORT
Could not allocate the necessary system resources to run this
test. This could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1002
ABORT
The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
TDM-BUS (TDM Bus) Maintenance documentation to
diagnose any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling
heavy traffic, repeat test at one-minute intervals a
maximum of 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors
present or some Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to TTR-LEV (TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to TONE-PT (Tone Generator) Maintenance
documentation.
3. If neither condition exists, retry the test at one-minute
intervals a maximum of 5 times.
1004
ABORT
The port was seized by a valid call during the test. The test has
been aborted. Use display port PCSSpp to determine the
station extension number of the port. Use status station to
determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for
certain tests. (Refer to the “Status Commands” section in
Chapter 10, “Maintenance Commands and Trouble-Clearing
Aids” for a full description of all possible states.) You must wait
until the port is idle before retesting. Attendants are always in
use (off-hook) if the handset is plugged in and the port is not
busied out.
1. Retry the command at one-minute intervals a maximum of
5 times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
2000
ABORT
Response to the test request was not received within the
allowable time period.
1. Retry the command at one-minute intervals a maximum of
5 times.
Table 10-326.
TEST #57 Hybrid Circuit and Conference Circuit Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...