Maintenance Object Repair Procedures
555-233-123
10-1464
Issue 4 May 2002
Analog Ring Generator Query Test (#118)
This test requests the Active Tone-Clock circuit pack to check the ringing voltage.
The tone/clock circuit pack replies with PASS if the ringing voltage is adequate to
ring the analog phones. If not, the active tone/clock circuit pack replies with a
FAIL. The Analog Ring Generator Query Test then reports the result.
Table 10-554.
TEST #117 Analog Ring Generator Initialization Test
Error
Code
Test
Result
Description/Recommendation
1
1000
1001
1003
1115
2012
2100
ABORT
The system software is unable to determine the active tone/clock
circuit pack, unable to allocated the resources necessary to run
the test, or unable to send a down link message.
1. Wait for the green LED on the active tone/clock to go out;
use the status port-network command to determine the
active Tone/Clock circuit pack.
2. Rerun the test. If the test aborts again, refer to TDM-CLK
Maintenance documentation.
2000
ABORT
Response to the request was not received within the allowable
time period.
1. Look for TDM-CLK errors and alarms. Resolve all other
Tone/Clock problems first.
2. Rerun the test.
1005
ABORT
The tone/clock is unable to read the analog ringing voltage level
when the tone/clock is in the Processor Interface slot. This test is
not available for the Processor Port Network in this configuration.
PASS
The active Tone/Clock has successfully been enabled to monitor
the ringing voltage level.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...