Maintenance Object Repair Procedures
555-233-123
10-1434
Issue 4 May 2002
■
40977 indicates that terminal equipment was not connected when
ringing was attempted. Run the short test via the test port
UUCSSpp command, and follow the procedure for the results of
Test #48.
b. Error Type: 15 - is a software audit error that does not indicate hardware
malfunction. Run the Short Test Sequence and investigate associated
errors.
c. Error Type: 257 - is an in-line error and can only be resolved over time.
This error indicates that ringing voltage is absent. If only one analog circuit
pack in the system has this problem, then replace the circuit pack. If only
analog circuit packs on a particular carrier have this error, then the ringing
generator may not be connected to this carrier. If analog circuit packs on
many carriers have this error, then it is probably a problem with the ringing
generator.
d. Error Type: 513 -Test #48 may cause some terminal equipment to ring
briefly during daily maintenance. If this disturbs the customer or the
terminal equipment, disable it by setting the
Tests
field on the change
station extension form to
n
. On some software releases, this will also
disable Tests #7 and 35.
e. Error Type 2817 - indicates that the end-point caused a large number of
control channel messages to be sent to the switch within a short period of
time (50 or more CCMS uplinks within 10 seconds). The station will be
taken out-of-service for 30 seconds due to the hyperactivity. This may be
completely normal during heavy traffic periods.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the Battery Feed
Test, for example, you may also clear errors generated from other tests in the
testing sequence.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/
ND
1
1
D = Destructive; ND = Nondestructive
Battery Feed Test (#35)
X
X
ND
Station Present Test (#48)
X
X
ND
Station Status and Translation Audits and
Updates Test (#36)
X
X
ND
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...