Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-352
Issue 4 May 2002
Page 4 - Endpoint Capability Information
This section describes fields specific to endpoint-level command output.
Screen 8-32.
Page 4 of 6: status conference x endpoint y
Endpoint Capability Information.
Fields on this page display if an endpoint
declares specific capability. For example, if an endpoint does not declare VID
H.CTX capability, the
H.CTX
field does not display.
FAS
Frame Alignment Signal (FAS) channel number (1 or 2). This
number should match the column header.
MCUFAL
MCU Frame Alignment Loss (MCUFAL). Counts the number of
times the MCU reports lost endpoint FAW or multichannel
synchronization (M-FRM) to the endpoint. The MCU a-bit
toggles when the MCU gains or loses endpoint multichannel
synchronization. This counter starts with 0x00, increments to
0xff, then wraps around to 0x01. The MCUFAL count also
displays in the
Fr Err
field on Page 2
FEFAL
Far End Frame Alignment Loss (FEFAL). Counts of the number
of changes the MCU detects in the endpoint’s a-bit (A-OUT).
The endpoint a-bit toggles when an endpoint gains or loses
MCU framing. This counter starts with 0x00, increments to 0xff,
then wraps around to 0x01.
status conference endpoint page 4 of 6
ENDPOINT CAPABILITY INFORMATION
--------------------------------------------------------------------------------
VID | vfmt: QCIF cmpi: 30 H.CTX SG4 imp
| da_sfg qmpi: 7.5 H.CTX+ SG4_sfg
-----|--------------------------------------------------------------------------
MISC | derestrict S/M mbe dcomp cic
-----|--------------------------------------------------------------------------
XR | 64 64x2 64x3 64x4 64x5 64x6 384 384x2 384x3 384x4 384x5
| 128 192 256 320 512 768 1152 1472 1536 1920
-----|--------------------------------------------------------------------------
AUD | ntrl 711m 711a g728 g722_64 g722_48
-----|--------------------------------------------------------------------------
LSD | var 300 1200 4800 6400 8000 9600 14.4k 16k 24k 32k 40k 48k 56k 62.4k 64k
-----|--------------------------------------------------------------------------
HSD | var 64k 128k 192k 256k 320k 348k 512k 768k 1152k 1536k
-----|--------------------------------------------------------------------------
MLP | var 4k 6.4k 14.4k 16k 22.4k 24k 30.4k 32k 38.4k 40k 46.4k 62.4k
-----|--------------------------------------------------------------------------
HMLP | var 62.4k 68k 128k 192k 256k 320k 384k
--------------------------------------------------------------------------------
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...