Maintenance Object Repair Procedures
555-233-123
10-628
Issue 4 May 2002
1039
ABORT
The DS1 Interface circuit pack is providing timing for the system.
Therefore, it cannot be reset without major system disruption.
1. If the DS1 Interface circuit pack needs to be tested, set the
synchronization reference to another DS1 Interface circuit
pack or to the Tone-Clock circuit pack via the following
command sequence:
■
Issue the disable synchronization-switch command.
■
Next, issue the set synchronization UUCSS command.
■
Lastly, issue the enable synchronization-switch
command.
2000
ABORT
The test was aborted. Response to the test was not received
within the allowable time period. This may be due to
hyperactivity. Error type 1538 in the error log indicates
hyperactivity. The hyperactive circuit pack is out of service and
one or more of the following symptoms may be exhibited.
1. The DS1-BD tests (such as Test 139 and Test 140) are
aborting with error code 2000.
2. The tests run on the ports of this circuit pack are returning a
no board result.
3. A busyout or a release command has no affect on the test
results.
4. A list config command shows that the circuit pack and the
ports are properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is isolated
from the system, and all of the trunks for this circuit pack
are placed into the out of service state. The system will
try to restore the circuit pack within 15 minutes. When no
faults are detected for 15 minutes, the DS1 interface
circuit pack is restored to normal operation. All of the
trunks for the DS1 interface circuit pack are then returned
to the in service state. Hyperactivity is often caused by
the associated facility. In such a case, faults (such as
slips, misframes, or blue alarms) would be entered in the
error log. In addition, many hardware errors would be
logged against the associated trunk circuits. If the facility
is OK and the error occurs again after 15 minutes,
escalate this problem
.
Table 10-234.
TEST #135 Internal Looparound Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...