FW-DWNLD (Firmware Download)
Issue 4 May 2002
10-867
555-233-123
1
FAIL
The firmware image file entered on the change firmware
download screen is not present on the source board specified in
the screen:
Execute list directory and verify that a file system is enabled on
the board and the file is present.
If the file system is not enabled, execute the enable filesystem
command and FTP the correct firmware image to the source
board. If the correct image file is present, then the name entered
on the screen is incorrect.
Execute change firmware download and enter the correct file
name.
2
FAIL
The image file header on the source board is invalid.
FTP a good firmware image file to the source board
3
FAIL
Firmware image file on the source board has a bad CRC.
FTP a good firmware image file to the source board.
4
FAIL
Firmware image file name is too long.
Rename the image file to a file name of the correct size.
FTP the new image file to the source board.
Execute change firmware download and enter the new file
name on the screen.
5
FAIL
The TN code of the firmware image file on the source board
does not match the TN code entered on the screen. The
firmware file is incorrect for the board type entered on the
screen.
Execute the list directory command and verify that a file system
is enabled on the board and the file is present.
If the file system is not enabled, execute enable filesystem and
FTP the correct firmware image to the source board.
Execute change firmware download and enter the new file
name on the screen.
Table 10-312.
TEST #1413 Firmware Download Test — Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...