
TSC-ADM (Administered Temporary Signaling
Connections)
Issue 4 May 2002
10-1825
555-233-123
2000
ABORT
The Administered TSC is not responding to a TSC heartbeat
inquiry.
1. Retry the test tsc-administered command at 1-minute
intervals a maximum of three times.
2. If the problem continues to fail, obtain the status of the
D-channel or D-channel pair associated with the
ADMTSC via status sig-group <group> . If the
D-channel is INS (that is, in-service) and the status of the
ADMTSC appears to be active, disable and enable the
ADMTSC through administration. NOTE: To disable the
ADMTSC, display the (administration) Signaling Group
Form via change sig-group <group> where <group>
refers to the number of the signaling group under which
the suspect TSC is administered. Change the "Enable"
field to "n." To enable the ADMTSC, change the "Enable"
field to "y."
3. Reissue the test tsc-administered command.
4. If the test fails, check the ADMTSC node on the other
side of the network to verify that the ADM TSC is indeed
active.
2012
ABORT
Internal System Error.
1. Reissue the test tsc-administered command at
1-minute intervals a maximum of 5 times.
1
FAIL
The Administered TSC is not active (far-end).
1. Reissue the test tsc-administered command.
2. Verify that the Administered TSC node on the other side
of the network is active.
3. Disable and enable the Administered TSC.
4. Retry the test tsc-administered command.
2
FAIL
Facility IE (Information Element) reject.
1. Check all other nodes in the network, and make sure
Administered TSC is active.
PASS
The Administered TSC responded to a heartbeat.
Table 10-663.
TEST #604 TSC Heartbeat Inquiry Test
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...