Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-182
Issue 4 May 2002
MST message types contain a version number. Whenever the structure of the
MST message changes, the version field in the MST buffer is changed. Version 1
displays a blank in the version field which is immediately after the MST message
type field. Subsequent versions display the version number after the MST
message type field and are connected with a hyphen (“-”). For example: Version 2
of the X.25 Application error/notification message has added the text of the pm
state table stimulus which was ignored.
Version 1 of MST message type 0xA2 appears on the ‘list mst’ output:
Version 2 of MST message type 0xA2 appears on the list mst output:
Vector Trace
Message type: 0x10
Message format:
Number
Date/Time
Type
Message
1
11:41:22:425
A2
17 10
Number
Date/Time
Type
Message
90
12:41:14:112
A2-02
17 10 21 03 32 05 01 80
Message[1-4]
= call identifier (CID) (defined in $BASEPJ/hdrs/capro.h)
Message[5-6]
= vector number (defined in $BASEPJ/hdrs/dpm_calls.h)
Message[7]
= step number (defined in $BASEPJ/hdrs/callr.h)
Message[8]
= step type (defined in $BASEPJ/hdrs/dpm_calls.h)
Message[9]
= step state (defined in $BASEPJ/hdrs/dpm_calls.h)
Message[10-12]
= VDN
Message[13]
= port network number
Message[14]
= endpoint number
Message[15]
= angel number
Message[16]
= circuit number
Message[17-20]
= trunk number
Message[21+]
= auxiliary data (based on step type)
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...