Maintenance Object Repair Procedures
555-233-123
10-484
Issue 4 May 2002
NPE Audit Test (#50)
The system updates the network connectivity information for all the NPEs on the
circuit pack through message to the on-board microprocessor. This test is
non-destructive.
Control Channel Loop Around Test (#52)
This non-destructive test queries the circuit pack for its code and vintage. This test
also verifies the circuit pack records.
Table 10-175.
TEST #50 NPE Audit Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run this
test.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1019
ABORT
Test already in progress.
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS
Circuit pack NPEs and translation updated.
Continued on next page
Table 10-176.
TEST #52 Control Channel Loop Around Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run this
test.
FAIL
Internal system error
1. Retry the command at 1-minute intervals, up to 5 times.
PASS
Successful communication with circuit pack.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...