Maintenance Object Repair Procedures
555-233-123
10-2006
Issue 4 May 2002
Notes:
a. This error indicates the circuit pack totally stopped functioning or it was
physically removed from the system. This error type is not applicable to
ANN-BD, DETR-BD, S-SYN-BD, M/T-BD, or CLSFY-BD.
NOTE:
The alarm is logged approximately 11 minutes after the circuit pack
has been removed and/or SAKI Sanity Test (#53) fails.
If the circuit pack is not in the system, insert a circuit pack (in the same slot
as the error indicates) to resolve this error. Or, if the circuit pack is in the
system and the red LED is on, follow the instructions for “Red (alarm)” in
the
‘‘Control and port circuit pack status LEDs’’
(See also the
‘‘Handling Control Circuit Packs’’
section in
Chapter 5, ‘‘Routine Maintenance Procedures’’
b. This error indicates the circuit pack has been busied out. Release the
circuit pack via release board PCSS.
c. The circuit pack has been logically administered but not physically
installed. The alarm should clear when the circuit pact is installed.
If the circuit pack is already installed:
1. Run test board PCSS long and look at any test failures or error
codes generated.
2. If the test does not clear error 23, then execute reset board PCSS
and run the long test again.
3. If the reset/test does not clear error 23, replace the circuit pack.
d. This error applies only to the Maintenance/Test circuit pack (TN771B or
TN771C). The error indicates that the hardware associated with the Analog
Trunk Testing port of the circuit pack failed to initialize. This port is not used
in G3iV1.1-286 or G3iV2-386. Note, however, that when this error occurs,
the Maintenance/Test circuit pack may report an invalid vintage. Although
this error is not service-affecting, the Maintenance/Test circuit pack should
be replaced.
e. A wrong circuit pack is inserted in the slot where this circuit pack is logically
administered. To resolve this problem, either remove the wrong circuit pack
and insert the logically administered circuit pack OR use the change
circuit-pack command to readminister this slot to match the circuit pack
inserted.
f. This error applies to the Maintenance/Test circuit pack (TN771D), Tone
Detector (TN748B, TN748C, or TN748D), and Call Classifier (TN748)
circuit packs. For the Maintenance/Test circuit pack, the error indicates that
there is more than one Maintenance/Test circuit pack in the port network.
For the Tone Detector or Call Classifier packs, the error indicates that there
are more than 10 circuit packs in the system. Remove the circuit pack
against which the error is logged.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...