DTMR-PT [Dual Tone Multifrequency Port (TTR)]
Issue 4 May 2002
10-699
555-233-123
1003
ABORT
The system could not allocate a Tone Generator for the test
connection. This could happen when the system is heavily
loaded or there is not a Tone-Clock circuit pack in the port
network when this test is being executed.
1. Make sure there is a Tone-Clock circuit pack in the same
port network.
2. If a Tone-Clock circuit pack is missing, install one in the
same port network.
3. Allow about one-minute for the Tone-Clock maintenance
to run on the newly inserted Tone-Clock circuit pack.
4. Retry the command at one-minute intervals a maximum of
5 times.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at one-minute intervals a maximum of
5 times.
2006
ABORT
DTMF detection failed. This could be caused by the
administered companding mode of the system not matching
that of the Tone Detector circuit pack.
1. Make sure that companding mode of the system matches
that of the Tone Detector.
1-3
FAIL
DTMF digits were not correctly detected.
1. Run the Short Test Sequence: test port PCSSpp sh r 1.
2. If the problem persists, the system is still operating
properly but system capacity will be reduced. In order to
restore the system performance to normal, replace the
Tone Detector circuit pack containing the defective DTMR
port.
PASS
The DTMR port is able to detect all the touch-tone digits.
Table 10-253.
TEST #42 Tone Detection Verification Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...