BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI
ISDN-BRI Port)
Issue 4 May 2002
10-275
555-233-123
Table 10-109.
TEST #617 Loop Around Test
Error
Code
Test
Result
Description/Recommendation
1000
ABORT
System resources required to run this test are not available.
The port may be busy with a valid call. Use the display port
PCSSpp command to determine the station extension or trunk
group/member number of the port. Use the status bri-port
PCSSpp command to determine the service state of the port.
If the service state indicates that the port is in use, then the
port is unavailable for certain tests. Wait until the port is idle
before retesting.
1. If the port status is idle, then retry the command at
1-minute intervals a maximum of 5 times.
1004
ABORT
The port has been seized by a user for a valid call. Use the
status station command for the station associated with this
port and determine when the port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
1005
ABORT
This test is not valid for this type of translation. Ports
administered as “ASAI” or “ADJK” cannot run this test,
because the B channels associated with the port are not used
by ASAI or Avaya Adjunct Links. This is a normal condition.
2012
ABORT
Internal System Error.
2100
ABORT
Could not allocate the necessary resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1, 2
FAIL
The NPE of the tested port was found to be transmitting in
error. This causes noisy and unreliable connections. Error
code 1 indicates that the NPE Crosstalk Test failed on
Channel B1. Error code 2 indicates that the NPE Crosstalk
Test failed on Channel B1.
1. Replace circuit pack.
PASS
The port is correctly using its allocated time slots.
1. To be sure that this is not an intermittent problem, repeat
this test a maximum of 10 times to make sure it continues
to pass.
2. If complaints still exist, examine the station, connections,
and wiring.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...