CO-TRK (CO Trunk)
Issue 4 May 2002
10-449
555-233-123
For the TN2147 World Class Central Office circuit pack, this test also checks the
on-board programmable transmission circuitry that allows the circuit pack to
support the transmission characteristics of several countries.
Table 10-166.
TEST #3 CO Demand Diagnostic Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1000
ABORT
System resources required to run this test are not available.
The port may be busy with a valid call. Use the display port
PCSSpp command to determine the trunk group/member
number of the port. Use the status trunk command to
determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for
certain tests. (Refer to the “Status Commands” section in
Chapter 10, “Maintenance Commands and Trouble-Clearing
Aids”, for a full description of all possible states.) You must wait
until the port is idle before retesting.
1. If the port status is idle, then retry the command at
1-minute intervals a maximum of 5 times.
1004
ABORT
The port was seized by a user for a valid call. Use the display
port PCSSpp command to determine the trunk group/member
number of the port. Use the status trunk command to
determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before
retesting.
1. If the port status is idle, retry the command at 1 minute
intervals for a maximum of 5 times.
1005
ABORT
Test inapplicable to present configuration. This is a normal
condition.
1018
ABORT
Test has been disabled via administration.
1. Verify that the “Maintenance Tests?” field on the Trunk
Group Form is set to “n”. To enable the test, issue the
change trunk-group x command where “x” equals the
number of the trunk group to be tested. Then change the
entry in the “Maintenance Tests?” field on the form to “y.”
2000
ABORT
Response to the request was not received within the allowable
time period.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...