PDMODULE, TDMODULE (Data Module)
Issue 4 May 2002
10-1197
555-233-123
3
ABORT
No response from EPF audit.
4
ABORT
Internal System Error.
1. Resolve any outstanding circuit pack maintenance
problems.
2. Retry the command at one-minute intervals a maximum of 5
times.
5
ABORT
Ringer update aborted (data module not in the in-service state).
1. Verify that the data module is powered (power LED on).
2. Make sure data module is connected to the building wiring,
check for faulty wiring, check for faulty data module.
3. Retry the command at one-minute intervals a maximum of 5
times.
4. Replace the Data Module and repeat the test.
5. If the test continues to abort, replace the Digital Line circuit
pack and repeat the test.
6
ABORT
Data module translation update aborted.
1. Verify the data module is connected to the PBX.
2. Retry the command at one-minute intervals a maximum of 5
times.
1000
ABORT
System resources required to run this test are not available.
2000
ABORT
Response to the test request was not received within the
allowable time period.
FAIL
Internal System Error.
1. Retry the command at one-minute intervals a maximum of 5
times.
PASS
Data Module Audits passed. This digital port circuit pack is
functioning properly.
1. If complaints still exist, investigate by using other port tests,
and by examining the data module options, wiring, and
connections.
Table 10-447.
TEST #17 Data Module Audits Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...