UDS1-BD (UDS1 Interface Circuit Pack)
Issue 4 May 2002
10-1869
555-233-123
1303
FAIL
The DS1 circuit pack Suffix is incorrect for CSU Module/T1 Sync
Splitter or E1 Sync Splitter administration.
The DS1 circuit pack Suffix is incorrect for CSU Module/T1 Sync
Splitter administration. The
Near-End CSU Type
field on the
add ds1 form has been administered as
integrated
but the
DS1 circuit pack is not a TN464F or later suffix UDS1 board.
1. If the CSU Module/T1 Sync Splitter is to be used, and the
Near-End CSU Type
field is set to
integrated
to
allow for CSU Module/T1 Sync Splitter administration,
remove the circuit pack and replace it with a TN464F or later
suffix board. Otherwise use the change ds1 command to
change the
Near-End CSU Type
field to
other
.
The DS1 circuit pack Suffix is incorrect for E1 Sync Splitter
administration. The
E1 Sync-Splitter?
field on the add
ds1 form has been administered as
y
but the DS1 circuit pack is
not a TN464F or later suffix UDS1 board.
1. If the E1 Sync Splitter is to be used, and the
E1
Sync-Splitter?
field is set to
y
to allow for E1SS
administration, remove the circuit pack and replace it with a
TN464F
or later suffix board. Otherwise use the change ds1
command to change the
E1 Sync-Splitter?
field to
n
.
1310
FAIL
The DS1 Board Loopback (BLB) demand test (#1209) failed.
1. Repeat the test using the test ds1-loop UUCSS
ds1/csu-loopback-tests command.
2. If the BLB test continues to fail, then replace the UDS1-BD
circuit pack.
3. Run this test again.
Table 10-673.
TEST #138 Loss of Signal Alarm Inquiry Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...