Maintenance Object Repair Procedures
555-233-123
10-946
Issue 4 May 2002
Signaling Link Board Check (#643)
This test checks the state of the UDS1 Interface circuit pack (TN464C or later)
transporting the ISDN-PRI Signaling Link.
Table 10-346.
TEST #643 Signaling Link Board Check
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
1700
ABORT
Rollabout video abort. The PRI terminal adapter associated
with this D-channel port is detached from the circuit pack. This
is a normal abort when the rollabout video feature is enabled.
To complete test on this port, either:
1. Re-attach the disconnected PRI terminal adapter and
retry test command, or
2. Disable the rollabout video feature on this circuit pack by
entering change ds1 PCCSS and set the field “Alarm
when PRI Endpoint Detached?” to “y.”
8
FAIL
The UDS1 circuit pack (TN464C or later) is not in-service.
1. Check the Hardware Error Log for entries logged against
UDS1-BD and consult the UDS1-BD (UDS1 Interface
Circuit Pack) Maintenance documentation for repair
procedures.
PASS
The UDS1 Interface circuit pack transporting the ISDN-PRI
Signaling Link Port is in-service.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...