Maintenance Object Repair Procedures
555-233-123
10-502
Issue 4 May 2002
2003
ABORT
Internal system error
1. Retry the command at 1-minute intervals, up to 5 times.
40
2000
2003
2004
FAIL
Error Code 40: Local Loop Back Test failed—data corrupt.
Error Code 2000-2004: Local Loop Back Test—data lost.
1. Determine if links exist on DATA-CHLs (status link).
2. Busyout the links to all DATA-CHLs (busyout link).
3. Test the target DATA-CHL (test data-module ext long).
4. If Test #107 result is FAIL, replace the Netcon or NetPkt
circuit pack when convenient.
5. Reset Time-of-Day clock on new circuit pack (set time).
6. Repeat the test.
7. If Test #107 result is PASS, and Test #108 result is FAIL,
replace the Netcon or NetPkt circuit pack when convenient.
8. Repeat the test.
9. If both Test #107 result and Test #108 results ARE PASS,
the target DATA-CHL is defective.
10. Remove target DATA-CHL from operation (remove
data-module ext).
11. Replace the Netcon or NetPkt circuit pack when convenient.
12. Reset Time-of-Day clock on new circuit pack (set time).
13. Restore any busied out links.
PASS
DATA-CHLs establish connections.
Table 10-183.
TEST #111 Data Channel Local Loop Back Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...