EXP-INTF (Expansion Interface Circuit Pack)
Issue 4 May 2002
10-765
555-233-123
Relationship Between Expansion Interface and
Tone-Clock Circuit Packs
The Expansion Interface fiber link depends on the system clock that is provided
by the Active Tone-Clock circuit pack on each network. (See TDM-CLK and
TONE-BD Maintenance documentation.) Each Expansion Interface circuit pack
transmits over the fiber at a rate derived from the system clock on its network. If
the Active Tone-Clock is defective to the point where the system clock frequency it
produces is out of the specified range (“out of spec”), an Expansion Interface Link
might go down even though the Expansion Interface circuit packs are healthy. In a
High or Critical Reliability system, both links could go down if there is a defective
Active Tone-Clock.
Whether or not a link goes down, depends on certain characteristics of the
Expansion Interface circuit packs. An Expansion Interface circuit pack should not
be replaced if the link on which it resides goes down because of a defective Active
Tone-Clock circuit pack. The defective Tone-Clock circuit pack should be replaced
instead. The Expansion Interface circuit packs are more sensitive to a defective
system clock than the rest of the components of the system. Therefore, testing of
the Tone-Clock circuit pack might not reveal a problem.
The symptoms of the problem in which an invalid system clock causes an
Expansion Link to go down are as follows:
1. If the Active PPN Tone-Clock circuit pack is providing an invalid system
clock:
a. The EPN Expansion Interface circuit pack yellow LED blinks quickly.
(Fiber Out-of-Frame condition).
If the EPN is up, Test #238 fails on this Expansion Interface circuit
pack.
b. The PPN Expansion Interface circuit pack yellow LED blinks slowly.
(In-frame, No Neighbor condition).
Test #237 fails on this Expansion Interface circuit pack, but Test
#238 passes.
2. If the EPN Tone-Clock circuit pack is providing an invalid system clock:
a. The PPN Expansion Interface circuit pack yellow LED blinks quickly
(Fiber Out-of-Frame condition).
Test #238 fails on this Expansion Interface circuit pack.
b. The EPN Expansion Interface circuit pack yellow LED blinks slowly
(In-frame, No Neighbor condition).
If the EPN is in-service, Test #237 fails on this Expansion Interface
circuit pack, but Test #238 passes.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...