TBRI-TRK (TN2185 ISDN Trunk-Side BRI)
Issue 4 May 2002
10-1691
555-233-123
ISDN Test Call Test (#258)
This test performs a far-end loop around to a far-end switch over an ISDN trunk.
The trunk’s service state must be in-service, maint-NE, or out-of-service/NE, and
no call can be active on the trunk.
Table 10-623.
TEST #257 Call State Audit Test
Error
Code
Test
Result
Description/Recommendation
1018
ABORT
The test is disabled.
1. Enable the test by entering y in the
Maintenance
Tests?
field on page 2 of the change trunk-group
form.
1019
ABORT
An audit is already in progress.
1. Wait two minutes and try again.
1113
ABORT
The signaling link has failed, so the system cannot send any
messages on behalf of this trunk.
1. Check the results of Test #1251 (Signaling Link State
Check).
1114
ABORT
The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1116
ABORT
The trunk is in an out-of-service ISDN service state.
1. A call cannot be present if the trunk is in an ISDN
out-of-service state, so a call state audit would be
inappropriate. No action necessary. (Use the status trunk
command.)
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS
The audit passed successfully.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...