Maintenance Object Repair Procedures
555-233-123
10-1746
Issue 4 May 2002
1003
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present or some of the tone detectors may be out of service.
Issue the list measurements tone-receiver command to
display basic information about the system’s tone receivers.
1. Look for TTR-LEV errors in the error log. If present, refer
to the TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the error log. If present, refer
to the TONE-PT Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute
intervals for a maximum of 5 times.
1004
ABORT
The port was seized by a user for a valid call. Use display
port UUCSSpp to determine the trunk group/member number
of the port. Use status trunk to determine the service state of
the port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. You must wait
until the port is idle before retesting.
1. If the port status is idle, retry the command at 1-minute
intervals for a maximum of 5 times.
1018
ABORT
Test disabled via administration. This only applies to analog
stations.
1. To enable test, set the Test field on the station
administration screen for the particular analog station
being tested to "y." Use change station <extension>.
1020
ABORT
The test did not run due to a previously existing error on the
specific port or because of a more general circuit pack error.
1. Examine the Error Log for existing errors against this port
or circuit pack, and attempt to diagnose the previously
existing error.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Table 10-643.
TEST #7 Conference Circuit Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...