M/T-PKT (Maintenance/Test Packet Bus Port)
Issue 4 May 2002
10-1161
555-233-123
Clear Error Counters (#270)
This test is not an actual test in the strict sense of the word. Many circuit packs
have counters in the Angel firmware. These counters are used so that CCMS
(Control Channel Message Set) messages are not continuously sent uplink. Using
this method, the message are sent once, when the counter reaches some preset
threshold, and then not sent again until the counter is cleared.
The ports on the Maintenance/Test circuit pack continually run self-tests,
whenever the port is idle. The Angel uses a counter so that the Background
Maintenance Failure message is only sent uplink once (this keeps a failed
port/circuit pack from flooding the SPE with a string of messages). This test is
used to clear the counter, so that if the port continues to fail during or after
SPE-demanded testing, the Angel sends a message to indicate that fact.
This test is only used to send a message to the Angel on the Maintenance/Test
circuit pack. Therefore, this test should never abort or fail.
Packet Bus Port Health Inquiry Test (#567)
This test verifies that the Packet Bus fault detection maintenance function of the
Maintenance/Test Packet Bus Port is functioning properly. This is done by having
the Maintenance/Test Packet Bus Port perform a self-test. If this self-test passes,
then the Packet Bus Port Health Inquiry Test passes. If the self-test fails, or the
SPE cannot communicate with the Maintenance/Test Packet Bus Port, then the
test fails.
Table 10-438.
TEST #270 Clear Error Counters
Error
Code
Test
Result
Description/Recommendation
Any
ABORT
This test should never abort.
Any
FAIL
This test should never fail.
1. Retry the command at one-minute intervals a maximum of
5 times.
PASS
The message to clear the Maintenance/Test circuit pack’s
counter for Background Maintenance Failures has been sent.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...