PPP-PT (Control LAN Packet/Port)
Issue 4 May 2002
10-1361
555-233-123
Session Status Test (#1286)
This non-destructive test determines the status of all PPP port sessions. This test
queries the system software on port session status.
2100
ABORT
Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
1003
FAIL
Ping to the destination failed due to on-board problem.
1. Retry the command at 1-minute intervals, up to 3 times.
2. If the problem persists, reset the circuit pack (busyout
board UUCSS, reset board UUCSS, and release board
UUCSS).
3. If the problem persists, re-administer the PPP connection
through a different PPP port, if available.
4. If the problem still persists, or if there are no other available
PPP ports, replace the circuit pack.
1007
FAIL
Ping to the destination failed due to the destination down.
1. A PPP destination or a component in the path (e.g., DS1
trunk) may be down. Check the status of the destination or
other components in the path.
2. If the destination and all components in the path are
in-service, ping the PPP destinations (ping ip-address
xxx.xxx.xxx.xxx).
3. Escalate if the problem persists.
PASS
TCP/IP Ping Test (#1281) is successful.
If the system software indicates that:
Then the switch:
All port sessions are up (ALL UP)
Raises no alarm, or retires alarm
Some port sessions are up (SOME UP)
Raises MINOR alarm
All port sessions are down (ALL DOWN)
Raises MINOR alarm
Table 10-502.
TEST #1281 TCP/IP Ping Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...