DUPINT (Duplication Interface Circuit Pack)
Issue 4 May 2002
10-719
555-233-123
Duplication Interface Circuit Pack Status Query
Test (#315)
This test is used to detect the presence of Duplication Interface circuit packs A
and B. To determine the status of Duplication Interface circuit pack B, a query is
sent to the Duplication Interface circuit pack A. To determine the status of
Duplication Interface circuit pack A, a query is sent to the Maintenance/Tape
Processor on the active carrier. The response to either query indicates the status
of the handshake to the appropriate Duplication Interface circuit pack.
Table 10-269.
TEST #315 Duplication Interface Circuit Pack
Status Query Test
Error
Code
Test
Result
Description/Recommendation
1000
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2000
ABORT
The software timed out waiting for the reply message.
1. Rerun the test.
2. If the message times out again, then continue to the next
step. If the query fails with a NO BOARD, then refer to NO
BOARD on the next page of this table.
3. No response is being received from the Duplication
Interface circuit pack or Maintenance/Tape Processor. If
Duplication Interface circuit pack A is under-test, then
check for and resolve all alarms against the active
PR-MAINT (Maintenance/Tape Processor). If Duplication
Interface circuit pack B is under test, then enter the test
dup a system technician command and resolve problems
with Test #315 for Duplication Interface circuit pack A first.
4. Rerun the test. If it still aborts, then a problem may exist
with one of the serial links. If carrier B is active or
Duplication Interface circuit pack B is under test, then the
serial link to get to Duplication Interface circuit pack B is
being carried by the ICC. Check for damage to the ICC,
and verify that all four connectors for the ICC are plugged
in. If the ICC has to be replaced, the system must be
powered down.
5. If the ICC is not the problem, then that portion of the serial
link wired into carrier A and/or carrier B may be defective,
and the carrier pack may need to be replaced.
2033
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...