Maintenance Object Repair Procedures
555-233-123
10-820
Issue 4 May 2002
External Device Alarm Test (#120)
The External Device Alarm Test requests the state of the External Device Alarm
from the Maintenance circuit pack and reports the results. The test has no effect
on the external device itself.
Table 10-299.
TEST #120 External Device Alarm Test
Error
Code
Test
Result
Description/Recommendation
1000
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2000
ABORT
Response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to ABORT with error code 2000, check
for system powering problems with the A carrier (PPN or
EPN). Look for and resolve all AC-POWER and
CARR-POW alarms in a multicarrier cabinet or
DC-POWER alarms in a single carrier cabinet. Then,
repeat the test.
3. If the test continues to ABORT with a 2000 error code,
check for and resolve all SYSAM errors in a PPN or
MAINT (EPN Maintenance circuit pack) errors in an EPN.
Then, repeat the test.
4. If the test continues to ABORT with a 2000 error code,
then escalate the problem.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...